← Back to the blog ITHKOR / research essays

From three bodies to a quantum test: when did the system get a nudge?

What can the last snapshot of a chaotic experiment tell us? From three bodies to a simulated quantum ring and a 0.40 → 0.55 prediction a lab can test.

Illustrative detail of a quantum computer cooling apparatus
Illustrative image created with AI.

It started with a question over coffee. Why are three moving bodies so hard to predict when we have known the rules for two for centuries? Precise rules can still produce unpredictable outcomes. In some systems, a tiny change at the start can send the trajectories far apart. We wondered about the reverse problem. Once we see the result, can we work out when something nudged the system?

Four snapshots instead of one

Picture a drop of ink in a glass of water. Once you stir it, the final colour gives little away about when the drop fell. Look while you are stirring and you might still catch a thin blue thread.

After simulating three bodies, we tried the idea on a Bose–Hubbard ring. Picture six wells in a circle and three particles that can hop between them. In the simulation, we compared a small error at the start with a nudge partway through. We matched the pairs so that at the end both cases were about equally far from the reference state.

With 8,000 simulated repetitions per case, a measurement at the end distinguished the two origins with 52.17% balanced accuracy. We split the same budget across four times after the nudge, subtracted the reference flow of particles and kept the sign of the difference. Accuracy rose to 73.22% across 2,048 held-out pairs. The simulation provided the reference. Simulation results

Where the hypothesis meets an experiment

ITHKOR explores the idea that a local quantum state can reach an information limit. In the closed model with fixed particle number, an operation confined to the monitored well could not change its distribution of particle counts. An open ring can lose a particle. An ordinary controller programmed to use a threshold can produce the same loss. So we ask what happens when we physically disconnect that feedback line.

In the model we used the capacity of a nearby register as a measurable threshold. The register stores three possible symbols. Its capacity tells us how much information can reliably make it through the readout. If that capacity sets the threshold in the monitored well, a nominally 92% accurate readout gives the first loss around 0.40, and a 99% accurate one gives it around 0.55. The units are set by the hopping rate in the model. The predicted chances of losing at least one particle at those times are about 6.11% and 5.45%. Exact version of the prediction

How to keep the analysis honest

The protocol compares two predetermined time windows and proposes 560 main trials, 280 per setting. Given the predicted effect, 80% detector efficiency and a 0.5% false-click probability per window, the calculation gives about a 92% chance of detecting both predicted differences. Calibration takes additional runs. Heating and crosstalk still need to be measured with feedback disconnected. Experimental protocol in Slovak

The evaluation script first processes the times without knowing the setting and records the result with a SHA-256 fingerprint. The trial assignments are revealed afterwards. A control copy deliberately flips some of the saved symbols. If that changes the reported timing of a particle loss, the analysis pipeline has a problem. Evaluation script

What we learned from real chips

We used a similar control on public data from other teams. In the Hassani study, increasing the readout power brought disagreement between two readings down from 17.20% to 11.00%. When we degraded the first record in software to match its original readout accuracy, disagreement rose to 15.71%. A change in the first readout’s error rate could therefore mimic much of the difference. Hassani et al. data · Analysis

In data from TU Delft, the team used the same final readout after a weaker or a stronger first pulse. The final readout agreed with the preparation in 70.14% versus 61.53% of trials. The 8.61 percentage point gap remained after matching first-readout accuracy in software using a separate calibration. This comparison shows why the effects of the pulse itself matter when changing the register. TU Delft data, v2 · Analysis

Other optical studies include two receivers watching the same pulse and settings with different readout accuracy. At 31 µW laser power, the researchers measured readout accuracy and converter thermal noise. The qubit coherence check was available at 3.1 µW and with the laser off. We still need an independent measurement of loss timing at two register capacities with comparable pulses, heating and crosstalk. Arnold et al. · van Thiel et al. · Fixed-pulse analysis

An invitation to labs

The 0.40 → 0.55 shift awaits a measurement in the ring. We invite experimental teams to test whether disconnecting the feedback and calibrating ordinary disturbances leaves a shift in when the detector registers particle loss. The public release includes the protocol, code, reproduction instructions and checksums. Its timestamp records publication. Research package · Release v1.0.0

Reaction

How did this essay land with you?

A quick reaction is sent to me by email. To develop the idea publicly, leave a comment below.

Discussion

Comments appear only after author approval. Each new comment triggers a moderation email.

There are no approved comments yet.

Leave a comment

Your email will not be published. The comment appears only after approval.